== Invalid transmission header ==
 
== Invalid transmission header ==
The software of the company "Greve Ingenieurleistungen" is lacking of correct support of the stream transmission header. It's impossible to communicate with their software.
+
The software "giodette" of the company "Greve Ingenieurleistungen" is lacking of correct support of the stream transmission header. It's impossible to communicate with their software.
 
=== Solution ===
 
=== Solution ===
 
None.
 
None.

Revision as of 14:11, 3 February 2012

OFTP error: no valid package received, but this binary content (8 bytes): '0x2 0x30 0x46 0x30 0x33 0xFE 0x27 0xD'

Hüngsberg offers an OFTP software called "Daxware". This bug has been reported in the middle of 2008 and has been accepted by Hüngsberg, but it seems they don't have the possibility to resolve it. The error itself contains a data package, which should be an OFTP package (with a given header):

0x2 0x30 0x46 0x30 0x33 0xFE 0x27 0xD

This message contains the following error:

0x46 0x30 0x33

which has an ASCII interpretation of

F    0     3

which means that the remote side indicated an OFTP session error 3:

A Start Session (SSID) command contains an unknown or invalid Identification Code.

which means that the remote partner doesn't has correctly configured your SSID.

Solution

Ask the remote party to update their OFTP settings for your partner entry. And, if you want, insist on an update of the remote software.

OFTP error: no valid package received, but this binary content (8 bytes): '0x2 0x30 0x46 0x30 0x34 0xFE 0x27 0xD'

Hüngsberg offers an OFTP software called "Daxware". This bug has been reported in the middle of 2008 and has been accepted by Hüngsberg, but it seems they don't have the possibility to resolve it. The error itself contains a data package, which should be an OFTP package (with a given header):

0x2 0x30 0x46 0x30 0x34 0xFE 0x27 0xD

This message contains the following error:

0x46 0x30 0x34

which has an ASCII interpretation of

F    0     4

which means that the remote side indicated an OFTP session error 4:

A Start Session (SSID) command contained an invalid password.

which means that the remote partner doesn't has correctly configured your OFTP password.

Solution

Ask the remote party to update their OFTP settings for your partner entry. And, if you want, insist on an update of the remote software.

Invalid transmission header

The software "giodette" of the company "Greve Ingenieurleistungen" is lacking of correct support of the stream transmission header. It's impossible to communicate with their software.

Solution